Name | Clayman-Jaffe Lens Manipulating Hook |
Lead Time | Lead time advised within 48 hours of order placement. |
Competitor | ;OP0923101;OP0923-101;350363;350-363;E0542;601309;60-1309;6013-09; |
Specialty | Ophthalmology-Hooks & Manipulators |
Material Finish | Stainless Steel |
Grade | Premium Operating Room |
Units of Measurement | Each |
Manufacturer | Tool Tectra |
Sterility | Non-Sterile |
Usage | Reusable |
Clayman-Jaffe Lens Manipulating Hook
9.0 mm shaft w/ 0.2 mm hook, angled 45 degrees, 4-3/4″ (12.0 cm)s Clayman-Jaffe Lens Manipulating Hook is a commonly used tool during cataract procedures. The hook is used to manipulate the opacified native lens during a phacoemulsification procedure. The 45 degree angled hook is ideal for moving the lens into a desired position for removal.
SKU:
TT-SI-5889
Category: Hooks &Manipulators
Description
Reviews (0)
Be the first to review “Clayman-Jaffe Lens Manipulating Hook” Cancel reply
Shipping & Delivery
Related products
Koch Stop & Chop Manipulator
SKU:
TT-SI-9889
angled shaft w/ 1.5 mm tip, 4-1/3" (11.2 cm)Â Koch Stop & Chop Manipulator is a tool used exclusively for cataract procedures. The manipulator is used to facilitate the stop and chop technique, in which the lens nucleus is initially sculpted and then chopped into smaller pieces for extraction. The angled shaft aids in accessing the lens capsule.
Maloney No-Hole Iol Manipulator
SKU:
TT-SI-2793
tear drop shape tip w/ post, 4-3/4" (12.0 cm)Â Maloney No-Hole IOL Manipulator is a useful tool for cataract procedures. The tear-drop shaped tip is ideal for manipulating the lens implant without risk of damaging or scratching. The extended working length allows the surgeon to maneuver the implant into the space desired.
Shepard Iris Hook
SKU:
TT-SI-8852
1.0 mm, blunt, 4-7/8" (12.4 cm)Â Shepard Iris Hook is a commonly used tool in cataract surgeries. The hook is used to retract a portion of the iris tissue to gain access to the lens capsule. Often, multiple hooks are used at different positions around the iris and anchored, providing adequate visualization for lens removal. The hook features a blunt tip to minimize extraneous tissue damage.
Kuglen Iris Hook & Lens Manipulator
SKU:
TT-SI-5257
straight shaft, 0.5 mm hook, blunt, 4-3/4" (12.0 cm)Â Kuglen Iris Hook & Lens Manipulator is a unique tool in cataract procedures. The tool may be used to pull the delicate iris tissue to expose the deeper lens capsule. In addition, the instrument is also meant to maneuver the native lens into a desirable position of phacoemulsification.
Jameson Muscle Hook
SKU:
TT-SI-3943
5-1/8" (13.0 cm)Â Jameson Muscle Hook is a useful tool in performing strabismus or other ophthalmologic procedures involving the ocular muscles. The hook can be used to elevate the muscle tissue for dissection and reattachment. The rounded tip ensures atraumatic entrance underneath the desired muscle. Two different sizes are available with the hook depending on surgical preference.
Kuglen Iris Hook & Lens Manipulator – Push-Pull Pattern
SKU:
TT-SI-7333
push-pull pattern, 4-1/2" (11.5 cm)Â Kuglen Iris Hook & Lens Manipulator is a multipurpose tool used in a variety of cataract procedures. The rounded button end is delicate enough to retract iris tissue to expose the anterior capsule of the lens. In addition, the instrument can be used to maneuver the lens into an ideal position for retraction. Both straight and angled models are available depending on physician preference.
Harris-Sinskey Lens Manipulating Hook
SKU:
TT-SI-7665
0.25 mm diameter, blunt tip, angled Harris-Sinskey Lens Manipulating Hook is a useful tool in cataract procedures. The hook may be used to maneuver lens tissue in order to facilitate extraction of the opacified tissue. The smaller diameter hook affords the surgeon increased control during the procedure. In addition, the blunt tip ensures minimal tissue damage or posterior capsule tear.
Hirschman Iris Hook
SKU:
TT-SI-1427
0.75 mm hook, angled, 4-3/4" (12.0 cm)Â Hirschman Iris Hook is a commonly used tool during cataract procedures and operations needing access to the lens capsule. The 0.75mm hook provides fine control while retracting only a selected portion of iris tissue. A blunted tip assures minimal tissue damage to the surrounding globe.
Reviews
There are no reviews yet.