Name | CV Elite – Titanium Kitzmiller Micro Clamp |
Lead Time | LEAD TIME ADVISED WITHIN 48 HOURS OF ORDER PLACEMENT. |
Specialty | Cardiothoracic-Clamps-Titanium Vascular Clamps – Delicate Clamps |
Material Finish | Titanium |
Grade | Premium Operating Room |
Units of Measurement | Each |
Manufacturer | Tool Tectra |
Sterility | Non-Sterile |
Usage | Reusable |
Titanium Kitzmiller Micro Clamp
Titanium Kitzmiller Micro Clamp
angled debakey jaws, 23.0 mm jaw length, 4-1/4″ (11.0 cm)
Titanium Kitzmiller Micro Clamp is designed for use in a variety of cardiothoracic surgeries where small vessels must be occluded. Because it’s made of blue-anodized titanium, the clamp is very light, reducing strain on the surgeon without sacrificing strength. It also is non-magnetic, meaning less hassle in the operating room. The jaw configuration features DeBakey serrations for atraumatic occlusion, and both left and right angled options.
SKU:
TT-SI-7595
Category: Cardiovascular Clamps
Description
Reviews (0)
Be the first to review “Titanium Kitzmiller Micro Clamp” Cancel reply
Shipping & Delivery
Related products
Cooley Acutely Curved Clamp
SKU:
TT-SI-6288
Cooley Acutely Curved Clamp
angled shanks, jaws calibrated at 5.0 mm intervals, 6-1/2" (16.5 cm)
Cooley Acutely Curved Clamp is designed for use in cardiothoracic surgeries. This instrument is designed to clamp vessels to reduce or completely block blood flow during surgery to allow the procedure to continue in a certain anatomical location where the blood is no longer able to flow through. These clamps feature an angled shanks as well as jaws calibrate at 5 mm intervals. Additionally, this instrument is available in three sizes: small, medium and large to accommodate a variety of patient sizes and a the wide variety of vessels that this clamp can be used on.
Cooley Multi Purpose Clamp
SKU:
TT-SI-5166
Cooley Multi Purpose Clamp
jaws angled 60 degrees
Cooley Multi Purpose Clamp is designed for use in a variety of cardiothoracic surgeries that require clamping of vessels. These multi-purpose clamps are uniquely designed to accommodate a number of different surgical maneuvers instead of being made for one specific purpose. The multiple application of this instrument making it a valuable tool in the operating room because it is suitable for most all clamping situations. Additionally, the jaws come angled at 60 degrees and this instrument is available in three different jaw lengths making it easy to find a suitable instrument for any surgical maneuver or surgeon preferences.
Cooley Iliac Clamp
SKU:
TT-SI-7926
Cooley Iliac Clamp
Cooley Iliac Clamp allows for exquisite control of blood flow through large arteries during a number of orthopedic and cardiac procedures, or whenever temporary occlusion of the iliac vasculature is desired. Renowned for its ease of use, Cooley Iliac Clamp is designed for the application of variable pressures on the Iliac artery to prevent intrusive blood flow. It provides for a strong, secure and adjustable grip which can be used for closure of vasculature or secure clamping of soft tissue. The jaws are set at a slight angle so as to allow maneuverability while still maintaining pressure and control when clamping the intended area. This clamp features straight jaws, handles angled at 45 degrees and is available in two different jaws sizes.
Cooley Renal Artery Clamp
SKU:
TT-SI-8791
Cooley Renal Artery Clamp
Cooley Renal Artery clamp is ideally suited for use in cardiothoracic surgeries. The slightly curved shanks and angled jaws make this clamp perfect for its ideal use which is as a renal clamp to fully or partially cause occlusion of the renal vessels. These jaws are atraumatic thus reducing injury and stress to the vessel walls while still remaining firmly in their affixed location. This instrument is available in three sizes: 7.25", 7.5" and 10.75" to accommodate a number of different surgical approaches and surgeon preferences.
Cooley Occlusion Clamp
SKU:
TT-SI-4458
Cooley Occlusion Clamp
curved jaws, jaws 3.6 cm long
Cooley Occlusion Clamp is designed for use in cardiothoracic surgical procedures. This clamp can be used to clamp vessels to reduce or stop blood flow to prevent the patient from losing an excessive amount of blood. The jaws allow for firm grasp of the vessels but with reduced risk of crushing or bruising to the vessel wall. Additionally, this clamp features curved shanks and jaws giving them a contour more suitable for use in vascular surgical procedures. This instrument is available in two different lengths to accommodate different vessel sizes and positions.
Exclusion Clamp
SKU:
TT-SI-2599
Exclusion Clamp
s shaped, curved jaws 8.5 cm, 7-1/4" (18.5 cm)
Aortic Exclusion Clamp are ideally made for use in cardiothoracic surgical procedures in which there is a need to exclude a certain portion of the aorta. The unique "S" shaped curvature of the jaws makes it contoured to fit the unique curvature and shapes necessary of atraumatic clamping of vessels. Although this instrument could have a wide application on other vessels it is designed for use in clamping of the aorta. This instrument is comprised of premium German operating-room grade stainless steel.
Beck Miniature Aorta Clamp – Stainless
SKU:
TT-SI-1882
Beck Miniature Aorta Clamp - Stainless
straight shanks, 6-3/4" (17.0 cm), debakey jaws, stainless
Beck Miniature Aorta clamp is designed for use in cardiothoracic surgeries. This miniature aorta clamp is ideally suited for use in neonatal or pediatric patients who have vessels that are too small to be handled by traditional sized instruments. This instrument can be used to clamp the aorta to occlude blood flow and prevent excessive bleeding during surgery. Additionally, this clamp is available with either DeBakey jaws or titanium jaws.
Cooley Coarctation Clamp – 6 3/4″
SKU:
TT-SI-3911
Cooley Coarctation Clamp - 6 3/4"
jaws calibrated at 5.0 mm intervals, 6-3/4" (17.1 cm
Cooley Coarctation Clamp is made for use in cardiothoracic surgical procedures. The ring handles make this instrument easy to handle and manipulate and the length of the tool allows the handle out of the surgical field. Additionally, the jaws are calibrate at 5.0 mm intervals and this instrument is available with straight shanks and straight, curved or spoon jaws, or angled shanks with straight jaws making it possible to find a suitable instrument for the particular surgical procedure.
Reviews
There are no reviews yet.