Name | CV Elite – Titanium Debakey Micro Clamp – Straight Jaws |
Lead Time | LEAD TIME ADVISED WITHIN 48 HOURS OF ORDER PLACEMENT. |
Specialty | Cardiothoracic-Clamps-Titanium Vascular Clamps – Delicate Clamps |
Material Finish | Titanium |
Grade | Premium Operating Room |
Units of Measurement | Each |
Manufacturer | Tool Tectra |
Sterility | Non-Sterile |
Usage | Reusable |
Titanium Debakey Micro Clamp – Straight Jaws
Titanium Debakey Micro Clamp – Straight Jaws
straight debakey jaws
Titanium DeBakey Micro Clamp is generally used for cardiothoracic surgeries to clamp smaller vessels. The clamp’s titanium composition makes it both lighter and stronger than the competition, so as to reduce hand strain, as well as making it non-magnetic. Its small jaw length gives it the control and precision needed to clamp small vessels, and the straight DeBakey jaws ensure atraumatic occlusion.
SKU:
TT-SI-9685
Category: Cardiovascular Clamps
Description
Reviews (0)
Be the first to review “Titanium Debakey Micro Clamp – Straight Jaws” Cancel reply
Shipping & Delivery
Related products
Cooley Anastomosis Clamp
SKU:
TT-SI-6776
Anastomosis Clamp
jaws calibrated at 5.0 mm intervals, 6-1/2" (16.5 cm)
Cooley Anastomosis Clamp is designed for use in cardiothoracic surgical procedures in which an anastomotic connection is to be formed between two vessels and blood flow needs to be reduce significantly via clamping. This instrument features jaws that are calibrated at 5 mm intervals making them ideally suited to give accurate measurement information during a surgical procedures. Additionally, this clamp features a slightly looped, u-shaped clamp to provide optimal gripping capacity but also maintaining that hold consistently throughout the procedure.
Cooley Neonatal Clamp
SKU:
TT-SI-2712
Cooley Neonatal Clamp
5" (12.5 cm)
Cooley Neonatal Clamp is the ideal tool for use in surgical procedures for newborn children. This clamp is build sturdily but made small enough to clamp the delicate vessels of a newborn child. This instrument is particularly well suited due to its ability to maintain a hold on the vessel without causing tears or rip on the delicate vessel walls of the newborn. Additionally, this clamp is available in a straight profile, spoon jawed, anastomosis clamp, carotid clamp or angled shank and straight jaws or curved shanks and angled jaws.
Cooley Iliac Clamp
SKU:
TT-SI-7926
Cooley Iliac Clamp
Cooley Iliac Clamp allows for exquisite control of blood flow through large arteries during a number of orthopedic and cardiac procedures, or whenever temporary occlusion of the iliac vasculature is desired. Renowned for its ease of use, Cooley Iliac Clamp is designed for the application of variable pressures on the Iliac artery to prevent intrusive blood flow. It provides for a strong, secure and adjustable grip which can be used for closure of vasculature or secure clamping of soft tissue. The jaws are set at a slight angle so as to allow maneuverability while still maintaining pressure and control when clamping the intended area. This clamp features straight jaws, handles angled at 45 degrees and is available in two different jaws sizes.
Cooley Miniature Multi Purpose Clamp
SKU:
TT-SI-5722
Cooley Miniature Multi Purpose Clamp
jaws calibrated at 5.0 mm intervals.
Cooley Miniature Multi Purpose Clamp is well suited for a variety of uses in cardiothoracic surgical procedures. Although this instrument does not have one particularly function but instead is a multi purpose clamp that can be used in a variety of different instances. The miniature size of this clamp makes it more able to reach certain vessels but also makes it better suited for use in smaller patients. This clamp comes equipped with jaws calibrated at 5 mm intervals and is available in three different angles 30, 60 and 90 degrees.
Cooley Cardiovascular Clamp – Fully-Curved
SKU:
TT-SI-6574
Fully-Curved
for temporary occulation of the iliac artery, 2-3/4" (7.0 cm) fully-curved jaws, 10-3/4" (27.3 cm)
Cooley Cardiovascular Clamp is ideally suited for use in cardiothoracic surgical procedures that require temporary occultation of the iliac artery. This instrument comes equipped with fully curved jaws making it particularly well suited for use in clamping vessels close to the diameter of the iliac vessels. The scissor grip handles and the ratcheting mechanism for keeping the clamp in place allows for this clamp to stay securely in place through the surgical procedure but is gentle enough to keep from injuring the vessel walls.
Beck Miniature Aorta Clamp – Titanium
SKU:
TT-SI-8416
Titanium
straight shanks, 6-3/4" (17.0 cm), debakey jaws, titanium
Beck Miniature Aorta clamp is designed for use in cardiothoracic surgeries. This miniature aorta clamp is ideally suited for use in neonatal or pediatric patients who have vessels that are too small to be handled by traditional sized instruments. This instrument can be used to clamp the aorta to occlude blood flow and prevent excessive bleeding during surgery. Additionally, this clamp is available with either DeBakey jaws or titanium jaws.
Castaneda Clamp
SKU:
TT-SI-2683
Castaneda Clamp
curved shanks, long thin jaw, calibrated jaws, horizontal serrations, 6" (15.0 cm)
Cataneda Clamp is a versatile tool made for use in cardiothoracic surgical procedures for newborn babies. This clamps are designed for neonatal use and as much are much smaller than their traditional counterpart but are equally effective. This multipurpose clamp is designed with curved shanks as well as long thing calibrated jaws coupled with horizontal serrations. Additionally, this instrument is available at varying angles and as a multi purpose or partially occluding clamp making it easy to find a perfect fit for any surgical procedure.
Cleveland Clinic Renal Clamp
SKU:
TT-SI-7857
Cleveland Clinic Renal Clamp
Cleveland Clinic Renal Clamp is a specialized piece of equipment designed for optimal use in cardiothoracic surgical procedures. This clamp is designed for use as a renal clamp to block or reduce blood flow through the renal vessels going to and from the kidney. To accommodate the positioning of these vessels this instrument comes with a significant angle to the jaws making access to the renal vasculature easier. This instrument is available angled either to the left or the right and also comes in either small or large jaws to accommodate a number of different patients sizes.
Reviews
There are no reviews yet.