Name | Maltzman-Fenzl Lens Manipulating Hook |
Lead Time | Lead time advised within 48 hours of order placement. |
Competitor | ;OP0923851;OP0923-851;601311;60-1311;6013-11;601312;60-1312;K3-5532;K35532;6013-12;6013-11_6013-12; |
Specialty | Ophthalmology-Hooks & Manipulators |
Material Finish | Stainless Steel |
Grade | Premium Operating Room |
Units of Measurement | Each |
Manufacturer | Tool Tectra |
Sterility | Non-Sterile |
Usage | Reusable |
Maltzman-Fenzl Lens Manipulating Hook
0.15 mm v-shaped tip, 4-3/4″ (12.0 cm)Â Maltzman-Fenzl Lens Manipulating Hook is a commonly used tool during cataract procedures. The hook is used to manipulate the opacified native lens during a phacoemulsification procedure. The tip contains 2 prongs designed to cup the lens in a variety of positions. Both angled and straight models are available with the hook depending on surgical preference.
SKU:
TT-SI-4155
Category: Hooks &Manipulators
Description
Reviews (0)
Be the first to review “Maltzman-Fenzl Lens Manipulating Hook” Cancel reply
Shipping & Delivery
Related products
Knolle Iris Hook
SKU:
TT-SI-5715
0.5 mm hook, 4-7/8" (12.4 cm)Â Knolle Iris Hook is a commonly used tool in cataract surgeries. The hook is used to retract a portion of the iris tissue to gain access to the lens capsule. Often, multiple hooks are used at different positions around the iris and anchored, providing adequate visualization for lens removal. The Knolle hook has a slender tip for more selective retraction while featuring a serrated handle for an improved grip.
Koch Stop & Chop Manipulator
SKU:
TT-SI-9889
angled shaft w/ 1.5 mm tip, 4-1/3" (11.2 cm)Â Koch Stop & Chop Manipulator is a tool used exclusively for cataract procedures. The manipulator is used to facilitate the stop and chop technique, in which the lens nucleus is initially sculpted and then chopped into smaller pieces for extraction. The angled shaft aids in accessing the lens capsule.
Hirschman Iris Hook
SKU:
TT-SI-1427
0.75 mm hook, angled, 4-3/4" (12.0 cm)Â Hirschman Iris Hook is a commonly used tool during cataract procedures and operations needing access to the lens capsule. The 0.75mm hook provides fine control while retracting only a selected portion of iris tissue. A blunted tip assures minimal tissue damage to the surrounding globe.
Sheets Iris Hook
SKU:
TT-SI-2855
0.3 mm hook w/ guard, 5-1/8" (13.0 cm)Â Sheets Iris Hook is a commonly used tool during cataract procedures and operations needing access to the lens capsule. The 0.3mm hook provides extra fine control in retracting only the desired portion of iris. In addition, the hook comes available with a guard to protect from damaging surrounding tissue.
Lewicky Lens Manipulating Hook
SKU:
TT-SI-2154
9.0 mm shaft, 90 degrees angled 2.0 mm tip, curved, 4-1/2" (11.5 cm)Â Lewicky Lens Manipulating Hook is a commonly used tool during cataract procedures. The hook is used to manipulate the opacified native lens during a phacoemulsification procedure. The extended length of the hook combined with the angled tip minimizes surgical obstruction during the procedure.
Maloney No-Hole Iol Manipulator
SKU:
TT-SI-2793
tear drop shape tip w/ post, 4-3/4" (12.0 cm)Â Maloney No-Hole IOL Manipulator is a useful tool for cataract procedures. The tear-drop shaped tip is ideal for manipulating the lens implant without risk of damaging or scratching. The extended working length allows the surgeon to maneuver the implant into the space desired.
Osher “Y” Hook Lens Manipulator
SKU:
TT-SI-6884
straight shaft, round handle, 4-3/4" (12.0 cm)Osher "Y" Hook Lens Manipulator is a commonly used tool during cataract procedures. The hook is used to manipulate the opacified native lens during a phacoemulsification procedure. The "Y" shape design allows for a more controlled grip of the lens and enhanced maneuverability.
Clayman-Jaffe Lens Manipulating Hook
SKU:
TT-SI-5889
9.0 mm shaft w/ 0.2 mm hook, angled 45 degrees, 4-3/4" (12.0 cm)s Clayman-Jaffe Lens Manipulating Hook is a commonly used tool during cataract procedures. The hook is used to manipulate the opacified native lens during a phacoemulsification procedure. The 45 degree angled hook is ideal for moving the lens into a desired position for removal.
Reviews
There are no reviews yet.