Name | Laufe Uterine Polyp Forceps |
Lead Time | 0-3 days |
Competitor | ;GL1820;505170;505-170;305605;30-5605;305640;30-5640;525129;52-5129;Gl1820;US132;5251-29; |
Specialty | Obstetrics & Gynecology-Forceps |
Material Finish | Stainless Steel |
Grade | Premium Operating Room |
Units of Measurement | Each |
Manufacturer | Tool Tectra |
Sterility | Non-Sterile |
Usage | Reusable |
Laufe Uterine Polyp Forceps
curved, serrated jaws, 8″ (20.3 cm) Â Laufe Uterine Polyp Forceps feature circular clamps at the end of ring handles for use in the removal of polyps from the uterus. The circular clamps have serrated jaws to firmly grasp the polyp for removal. They are curved to optimize visualization of the operating field during procedures.
Description
Reviews (0)
Be the first to review “Laufe Uterine Polyp Forceps” Cancel reply
Shipping & Delivery
Related products
Corson Myoma Grasping Forceps
SKU:
TT-SI-8188
Elliot Obstetrical Forceps
SKU:
TT-SI-4862
Elliot Obstetrical Forceps are commonly used to aid the mother in childbirth. The elongated, curved cephalic blades have an opening and are designed to grasp the child's head close to the pelvis. The handle is grooved for the obstetrician to allow a firm grip on the instrument while in use. Available in various lengths to accommodate a wide range of cases.
Barton Obstetrical Forceps
SKU:
TT-SI-7197
14" (35.5 cm) Barton Obstetrical Forceps are commonly used to aid in the delivery process when the fetal head is in the high transverse position, commonly seen during a cesarean delivery. The forceps feature a fixed posterior cephalic blade and a hinged anterior blade to firmly grasp the fetal head once locked. The blades are fenestrated to allow palpation by the surgeon and to provide minimal discomfort to the child's head.
Blumenthal Ovum Forceps
SKU:
TT-SI-4681
slightly curved, concave tip, 20.0 mm jaw, coarse teeth, 13" (33.0 cm) Blumenthal Ovum Forceps are ideal in the removal of placental tissue or other products of conception from the uterus to prevent infections. The hollow blades are slightly curved with coarse teeth on the jaws to firmly grasp the tissue to be removed. The concave tip is designed to prevent grasping the fundus of the uterus.
Clark Forceps
SKU:
TT-SI-6294
Bierer Tenaculum
SKU:
TT-SI-5734
angled jaws, 5x6 teeth, 9" (22.9 cm) Â Bierer Tenaculum is commonly used in gynecology to stabilize a woman's cervix or uterus during a procedure. The tenaculum features angled jaws and inward facing hooks with 5X6 teeth to firmly grasp the tissue. The ring handles have a lock mechanism to hold the blades in various positions.
Heaney Hysterectomy Forceps
SKU:
TT-SI-6362
Heaney Hysterectomy Forceps are commonly used during the hysterectomy procedure to clamp off a tough ligament on both sides of the uterus. The forceps feature ring handles with a lock mechanism and serrated blades to firmly grasp the ligament. Available straight or curved with single or double grooves on the blades in various lengths to accommodate a wide range of cases.
Faure Peritoneal Clamp Forceps
SKU:
TT-SI-9295
slight curve, 8-1/4" (21.0 cm)Â Faure Peritoneal Clamp Forceps are commonly used to remove the peritoneum tissue from the pelvic cavity for gynecological procedures. The ring handles feature a locking mechanism to hold the forceps in position. The slightly curved serrated blades keep a firm grip on the peritoneal tissue during the procedure.
Reviews
There are no reviews yet.