Name | CV Elite – Dennis-Style Anastomosis Clamp – Debakey Jaws |
Lead Time | LEAD TIME ADVISED WITHIN 48 HOURS OF ORDER PLACEMENT. |
Specialty | Cardiothoracic-Clamps-Stainless Vascular Clamps – Standard Clamps |
Material Finish | Stainless Steel |
Grade | Premium Operating Room |
Units of Measurement | Each |
Manufacturer | Tool Tectra |
Sterility | Non-Sterile |
Usage | Reusable |
CV Elite – Dennis-Style Anastomosis Clamp – Debakey Jaws
CV Elite – Dennis-Style Anastomosis Clamp – Debakey Jaws
debakey jaws, 7″ (18.0 cm)
Dennis Style Anastomosis Clamp with DeBakey Jaws is designed for use in a variety of cardiovascular surgical operations where anastomosis is required. The hook shape allows for a superior range in the surgical field while the DeBakey Jaw Structure ensures atraumatic occlusion of the vessel with superior grip. The instrument comes in a variety of hook styles to match surgeons’ preferences and specific procedural needs.
SKU:
TT-SI-2743
Category: Cardiovascular Clamps
Description
Reviews (0)
Be the first to review “CV Elite – Dennis-Style Anastomosis Clamp – Debakey Jaws” Cancel reply
Shipping & Delivery
Related products
Cooley Renal Artery Clamp
SKU:
TT-SI-8791
Cooley Renal Artery Clamp
Cooley Renal Artery clamp is ideally suited for use in cardiothoracic surgeries. The slightly curved shanks and angled jaws make this clamp perfect for its ideal use which is as a renal clamp to fully or partially cause occlusion of the renal vessels. These jaws are atraumatic thus reducing injury and stress to the vessel walls while still remaining firmly in their affixed location. This instrument is available in three sizes: 7.25", 7.5" and 10.75" to accommodate a number of different surgical approaches and surgeon preferences.
Cooley Anastomosis Clamp
SKU:
TT-SI-6776
Anastomosis Clamp
jaws calibrated at 5.0 mm intervals, 6-1/2" (16.5 cm)
Cooley Anastomosis Clamp is designed for use in cardiothoracic surgical procedures in which an anastomotic connection is to be formed between two vessels and blood flow needs to be reduce significantly via clamping. This instrument features jaws that are calibrated at 5 mm intervals making them ideally suited to give accurate measurement information during a surgical procedures. Additionally, this clamp features a slightly looped, u-shaped clamp to provide optimal gripping capacity but also maintaining that hold consistently throughout the procedure.
Cooley Coarctation Clamp – 6 3/4″
SKU:
TT-SI-3911
Cooley Coarctation Clamp - 6 3/4"
jaws calibrated at 5.0 mm intervals, 6-3/4" (17.1 cm
Cooley Coarctation Clamp is made for use in cardiothoracic surgical procedures. The ring handles make this instrument easy to handle and manipulate and the length of the tool allows the handle out of the surgical field. Additionally, the jaws are calibrate at 5.0 mm intervals and this instrument is available with straight shanks and straight, curved or spoon jaws, or angled shanks with straight jaws making it possible to find a suitable instrument for the particular surgical procedure.
Cooley Multi Purpose Clamp
SKU:
TT-SI-5166
Cooley Multi Purpose Clamp
jaws angled 60 degrees
Cooley Multi Purpose Clamp is designed for use in a variety of cardiothoracic surgeries that require clamping of vessels. These multi-purpose clamps are uniquely designed to accommodate a number of different surgical maneuvers instead of being made for one specific purpose. The multiple application of this instrument making it a valuable tool in the operating room because it is suitable for most all clamping situations. Additionally, the jaws come angled at 60 degrees and this instrument is available in three different jaw lengths making it easy to find a suitable instrument for any surgical maneuver or surgeon preferences.
Beck Miniature Aorta Clamp – Stainless
SKU:
TT-SI-1882
Beck Miniature Aorta Clamp - Stainless
straight shanks, 6-3/4" (17.0 cm), debakey jaws, stainless
Beck Miniature Aorta clamp is designed for use in cardiothoracic surgeries. This miniature aorta clamp is ideally suited for use in neonatal or pediatric patients who have vessels that are too small to be handled by traditional sized instruments. This instrument can be used to clamp the aorta to occlude blood flow and prevent excessive bleeding during surgery. Additionally, this clamp is available with either DeBakey jaws or titanium jaws.
Bailey Aorta Clamp
SKU:
TT-SI-1643
Bailey Aorta Clamp
angled shanks
Bailey Aorta Clamp are designed for use in cardiothoracic surgical procedures. This clamp is ideal for use when there is a surgical maneuver that requires exclusion of a specific portion of the vessel. The unique design of this clamp with the slightly angled shanks allows for this clamp to effectively reach and clamp off the aorta when other instruments may not be able to. Additionally, this instrument is available in three different jaw sizes: extra small, small and large making it well suited for a number of different vessel sizes but also in different levels of blood flow restriction.
Cooley Pediatric Clamp
SKU:
TT-SI-5455
Cooley Pediatric Clamp
delicate clamp, jaws calibrated at 5.0 mm intervals, 5-1/2" (14.0 cm)
Cooley Pediatric Clamp is ideally suited for clamping in cardiothoracic surgical procedures with pediatric patients. This clamp features jaws that are calibrated at 5.0 mm intervals but are still delicate enough for use in pediatric surgeries. This instrument is designed to keep a firm hold on the vessels that are being occluded but delicate enough not to bruise or tear the vessels thus reducing the amount of damage done to the patient. This clamp is available in a number of different styles that include straight or angled shanks and straight, satinsky, angled, or spoon-shaped jaws making this instrument highly versatile and useful in the operating room.
Beck Miniature Aorta Clamp – Titanium
SKU:
TT-SI-8416
Titanium
straight shanks, 6-3/4" (17.0 cm), debakey jaws, titanium
Beck Miniature Aorta clamp is designed for use in cardiothoracic surgeries. This miniature aorta clamp is ideally suited for use in neonatal or pediatric patients who have vessels that are too small to be handled by traditional sized instruments. This instrument can be used to clamp the aorta to occlude blood flow and prevent excessive bleeding during surgery. Additionally, this clamp is available with either DeBakey jaws or titanium jaws.
Reviews