Name | Cooley Patent Ductus Clamp – 8″ |
Lead Time | Lead time advised within 48 hours of order placement. |
Specialty | Cardiothoracic-Cardiovascular Clamps |
Material Finish | Stainless Steel |
Grade | Premium Operating Room |
Units of Measurement | Each |
Manufacturer | Tool Tectra |
Sterility | Non-Sterile |
Usage | Reusable |
Cooley Patent Ductus Clamp – 8″
Cooley Patent Ductus Clamp – 8″
jaws 3.0 cm long, 8″ (20.0 cm)
Cooley Patent Ductus Clamp is ideally suited for aortic and pulmonary clamping in cardiothoracic surgical procedures used to treat patent ductus arteriosus (PDA). The ring handles of this clamp make it easy to maneuver in the surgical field. Additionally, the ratcheting mechanism allows the tension to be controlled and set to accommodate the particular situation so either full clamping or only partial blockage. This clamp is available with either straight or curved shanks making it suitable for a number of patient scenarios and surgeon preferences.
SKU:
TT-SI-3528
Category: Cardiovascular Clamps
Description
Reviews (0)
Be the first to review “Cooley Patent Ductus Clamp – 8″” Cancel reply
Shipping & Delivery
Related products
Cooley Coarctation Clamp – 6 3/4″
SKU:
TT-SI-3911
Cooley Coarctation Clamp - 6 3/4"
jaws calibrated at 5.0 mm intervals, 6-3/4" (17.1 cm
Cooley Coarctation Clamp is made for use in cardiothoracic surgical procedures. The ring handles make this instrument easy to handle and manipulate and the length of the tool allows the handle out of the surgical field. Additionally, the jaws are calibrate at 5.0 mm intervals and this instrument is available with straight shanks and straight, curved or spoon jaws, or angled shanks with straight jaws making it possible to find a suitable instrument for the particular surgical procedure.
Cherry Supraceliac Clamp
SKU:
TT-SI-1517
Cherry Supraceliac Clamp
shanks curved 60 degrees, debakey 2x3 teeth, jaws 5-3/4", curved, 12-1/2" (31.0 cm)
Cheery Supraceliac Clamp is created to be of optimal use in cardiothoracic surgical procedures. This instrument is especially useful aortic aneurysm repairs of the abdominal and thoracic aorta particularly this clamp can be used in accessing the portion of the aorta that is found superior to the celiac artery. Curved shanks coupled with a 60 degree angle and DeBakey teeth allow this clamp to access some deeper vessel structures without damaging the vessel walls or the surrounding tissue.
Cleveland Clinic Renal Clamp
SKU:
TT-SI-7857
Cleveland Clinic Renal Clamp
Cleveland Clinic Renal Clamp is a specialized piece of equipment designed for optimal use in cardiothoracic surgical procedures. This clamp is designed for use as a renal clamp to block or reduce blood flow through the renal vessels going to and from the kidney. To accommodate the positioning of these vessels this instrument comes with a significant angle to the jaws making access to the renal vasculature easier. This instrument is available angled either to the left or the right and also comes in either small or large jaws to accommodate a number of different patients sizes.
Cooley Renal Artery Clamp
SKU:
TT-SI-8791
Cooley Renal Artery Clamp
Cooley Renal Artery clamp is ideally suited for use in cardiothoracic surgeries. The slightly curved shanks and angled jaws make this clamp perfect for its ideal use which is as a renal clamp to fully or partially cause occlusion of the renal vessels. These jaws are atraumatic thus reducing injury and stress to the vessel walls while still remaining firmly in their affixed location. This instrument is available in three sizes: 7.25", 7.5" and 10.75" to accommodate a number of different surgical approaches and surgeon preferences.
Beck Miniature Aorta Clamp – Stainless
SKU:
TT-SI-1882
Beck Miniature Aorta Clamp - Stainless
straight shanks, 6-3/4" (17.0 cm), debakey jaws, stainless
Beck Miniature Aorta clamp is designed for use in cardiothoracic surgeries. This miniature aorta clamp is ideally suited for use in neonatal or pediatric patients who have vessels that are too small to be handled by traditional sized instruments. This instrument can be used to clamp the aorta to occlude blood flow and prevent excessive bleeding during surgery. Additionally, this clamp is available with either DeBakey jaws or titanium jaws.
Cooley Acutely Curved Clamp
SKU:
TT-SI-6288
Cooley Acutely Curved Clamp
angled shanks, jaws calibrated at 5.0 mm intervals, 6-1/2" (16.5 cm)
Cooley Acutely Curved Clamp is designed for use in cardiothoracic surgeries. This instrument is designed to clamp vessels to reduce or completely block blood flow during surgery to allow the procedure to continue in a certain anatomical location where the blood is no longer able to flow through. These clamps feature an angled shanks as well as jaws calibrate at 5 mm intervals. Additionally, this instrument is available in three sizes: small, medium and large to accommodate a variety of patient sizes and a the wide variety of vessels that this clamp can be used on.
Cooley Pediatric Clamp
SKU:
TT-SI-5455
Cooley Pediatric Clamp
delicate clamp, jaws calibrated at 5.0 mm intervals, 5-1/2" (14.0 cm)
Cooley Pediatric Clamp is ideally suited for clamping in cardiothoracic surgical procedures with pediatric patients. This clamp features jaws that are calibrated at 5.0 mm intervals but are still delicate enough for use in pediatric surgeries. This instrument is designed to keep a firm hold on the vessels that are being occluded but delicate enough not to bruise or tear the vessels thus reducing the amount of damage done to the patient. This clamp is available in a number of different styles that include straight or angled shanks and straight, satinsky, angled, or spoon-shaped jaws making this instrument highly versatile and useful in the operating room.
Cooley Cardiovascular Clamp
SKU:
TT-SI-2459
Cooley Cardiovascular Clamp
2" (5.1 cm) curved jaws, 10-3/4" (27.3 cm)
Cooley Cardiovascular Clamp is an ideal tool for use in cardiothoracic surgical procedures that require clamping of vessels to prevent excessive bleeding. This instrument is designed with two inch curved jaws that allow for stable closure of vessel while maintaining gentle enough pressure on the vessel wall to prevent damage or tearing. Additionally, this clamp features a ratcheting mechanisms to keep the clamp locked in place during surgery.
Reviews
There are no reviews yet.