| Name | Cooley Aortic Aneurysm Clamp |
| Lead Time | Lead time advised within 48 hours of order placement. |
| Specialty | Cardiothoracic-Cardiovascular Clamps |
| Material Finish | Stainless Steel |
| Grade | Premium Operating Room |
| Units of Measurement | Each |
| Manufacturer | Tool Tectra |
| Sterility | Non-Sterile |
| Usage | Reusable |
Cooley Aortic Aneurysm Clamp
Cooley Aortic Aneurysm Clamp
slightly curved jaws, jaws 7.6 cm, 10-3/4″ (27.3 cm)
Cooley Aortic Aneurysm Clamp is made to be used cardiothoracic procedures that require clamping of the aorta, specifically at or around the site of aneurysm. This clamp can be used to in temporary occlusion of the aorta to resect fusiform aneurysms as well as provide additional support and stability in aortic grafting procedures. The slightly curved jaws gives this clamp the ability to contour to and seamlessly move through the surgical field causing the least amount of trauma to the aorta itself and surrounding tissue.
SKU:
TT-SI-2373
Category: Cardiovascular Clamps
Description
Reviews (0)
Be the first to review “Cooley Aortic Aneurysm Clamp” Cancel reply
Shipping & Delivery
Related products
Beck Vascular Clamp
SKU:
TT-SI-1222
Beck Vascular Clamp
cooley jaws calibrated at 5.0 mm intervals, straight shanks, 6" (15.0 cm)
Beck Vascular Clamp is suited for optimal use in cardiothoracic surgical procedures. This clamp is designed to clamp vessels and occlude blood flow during surgical procedures in many cases to prevent an excessive amount of blood loss from the patient. A unique feature of this clamp is the curved Cooley jaws that are calibrated at 50 mm intervals as well as the straight shanks. This instrument is available two sizes: small jaw with heavy curvature and large jaw with medium curvature.
Cooley Acutely Curved Clamp
SKU:
TT-SI-6288
Cooley Acutely Curved Clamp
angled shanks, jaws calibrated at 5.0 mm intervals, 6-1/2" (16.5 cm)
Cooley Acutely Curved Clamp is designed for use in cardiothoracic surgeries. This instrument is designed to clamp vessels to reduce or completely block blood flow during surgery to allow the procedure to continue in a certain anatomical location where the blood is no longer able to flow through. These clamps feature an angled shanks as well as jaws calibrate at 5 mm intervals. Additionally, this instrument is available in three sizes: small, medium and large to accommodate a variety of patient sizes and a the wide variety of vessels that this clamp can be used on.
Cooley Patent Ductus Clamp – 6 1/4″
SKU:
TT-SI-2718
Cooley Patent Ductus Clamp - 6 1/4"
jaws calibrated at 5.0 mm intervals, 6-1/4" (16.0 cm)
Cooley Patent Ductus clamp is well suited for use in cardiothoracic surgical procedures. Specifically this clamp is designed for use in surgical procedures to repair a patent ductus. The jaws of this clamp are calibrated at 5 mm intervals and are designed for a firm surgical grip upon the vessels but is delicate enough to prevent any bruising or tears to the vessels walls themselves. This instrument is available with either straight or angular shanks making it possible to select the best fit possible for the procedure at hand.
Cooley Anastomosis Clamp
SKU:
TT-SI-6776
Anastomosis Clamp
jaws calibrated at 5.0 mm intervals, 6-1/2" (16.5 cm)
Cooley Anastomosis Clamp is designed for use in cardiothoracic surgical procedures in which an anastomotic connection is to be formed between two vessels and blood flow needs to be reduce significantly via clamping. This instrument features jaws that are calibrated at 5 mm intervals making them ideally suited to give accurate measurement information during a surgical procedures. Additionally, this clamp features a slightly looped, u-shaped clamp to provide optimal gripping capacity but also maintaining that hold consistently throughout the procedure.
Cooley Auricular Appendage Forceps
SKU:
TT-SI-2552
Cooley Auricular Appendage Forceps
1-5/8" x 3/8" (4.1 cm x 1.0 cm) jaws, 10" (25.4 cm)
Cooley Auricular Appendage Forceps are specially designed for use in cardiothoracic surgical procedures. These forceps have a wide application but are particularly well suited for use in manipulating auricular appendages. Each auricle leads into its respective atrium and thus this instrument is of use in surgical procedures that require access to the atria. The scissor handle grip allows for ease in grasping and manipulating this tool.
Beck Miniature Aorta Clamp – Titanium
SKU:
TT-SI-8416
Titanium
straight shanks, 6-3/4" (17.0 cm), debakey jaws, titanium
Beck Miniature Aorta clamp is designed for use in cardiothoracic surgeries. This miniature aorta clamp is ideally suited for use in neonatal or pediatric patients who have vessels that are too small to be handled by traditional sized instruments. This instrument can be used to clamp the aorta to occlude blood flow and prevent excessive bleeding during surgery. Additionally, this clamp is available with either DeBakey jaws or titanium jaws.
Cooley Cardiovascular Clamp – Fully-Curved
SKU:
TT-SI-6574
Fully-Curved
for temporary occulation of the iliac artery, 2-3/4" (7.0 cm) fully-curved jaws, 10-3/4" (27.3 cm)
Cooley Cardiovascular Clamp is ideally suited for use in cardiothoracic surgical procedures that require temporary occultation of the iliac artery. This instrument comes equipped with fully curved jaws making it particularly well suited for use in clamping vessels close to the diameter of the iliac vessels. The scissor grip handles and the ratcheting mechanism for keeping the clamp in place allows for this clamp to stay securely in place through the surgical procedure but is gentle enough to keep from injuring the vessel walls.
Cleveland Clinic Renal Clamp
SKU:
TT-SI-7857
Cleveland Clinic Renal Clamp
Cleveland Clinic Renal Clamp is a specialized piece of equipment designed for optimal use in cardiothoracic surgical procedures. This clamp is designed for use as a renal clamp to block or reduce blood flow through the renal vessels going to and from the kidney. To accommodate the positioning of these vessels this instrument comes with a significant angle to the jaws making access to the renal vasculature easier. This instrument is available angled either to the left or the right and also comes in either small or large jaws to accommodate a number of different patients sizes.

Reviews
There are no reviews yet.