Name | Cooley Acutely Curved Clamp |
Lead Time | Lead time advised within 48 hours of order placement. |
Specialty | Cardiothoracic-Cardiovascular Clamps |
Material Finish | Stainless Steel |
Grade | Premium Operating Room |
Units of Measurement | Each |
Manufacturer | Tool Tectra |
Sterility | Non-Sterile |
Usage | Reusable |
Cooley Acutely Curved Clamp
Cooley Acutely Curved Clamp
angled shanks, jaws calibrated at 5.0 mm intervals, 6-1/2″ (16.5 cm)
Cooley Acutely Curved Clamp is designed for use in cardiothoracic surgeries. This instrument is designed to clamp vessels to reduce or completely block blood flow during surgery to allow the procedure to continue in a certain anatomical location where the blood is no longer able to flow through. These clamps feature an angled shanks as well as jaws calibrate at 5 mm intervals. Additionally, this instrument is available in three sizes: small, medium and large to accommodate a variety of patient sizes and a the wide variety of vessels that this clamp can be used on.
SKU:
TT-SI-6288
Category: Cardiovascular Clamps
Description
Reviews (0)
Be the first to review “Cooley Acutely Curved Clamp” Cancel reply
Shipping & Delivery
Related products
Cooley Cardiovascular Clamp – Fully-Curved
SKU:
TT-SI-6574
Fully-Curved
for temporary occulation of the iliac artery, 2-3/4" (7.0 cm) fully-curved jaws, 10-3/4" (27.3 cm)
Cooley Cardiovascular Clamp is ideally suited for use in cardiothoracic surgical procedures that require temporary occultation of the iliac artery. This instrument comes equipped with fully curved jaws making it particularly well suited for use in clamping vessels close to the diameter of the iliac vessels. The scissor grip handles and the ratcheting mechanism for keeping the clamp in place allows for this clamp to stay securely in place through the surgical procedure but is gentle enough to keep from injuring the vessel walls.
Cleveland Clinic Renal Clamp
SKU:
TT-SI-7857
Cleveland Clinic Renal Clamp
Cleveland Clinic Renal Clamp is a specialized piece of equipment designed for optimal use in cardiothoracic surgical procedures. This clamp is designed for use as a renal clamp to block or reduce blood flow through the renal vessels going to and from the kidney. To accommodate the positioning of these vessels this instrument comes with a significant angle to the jaws making access to the renal vasculature easier. This instrument is available angled either to the left or the right and also comes in either small or large jaws to accommodate a number of different patients sizes.
Cooley Patent Ductus Clamp – 6 1/4″
SKU:
TT-SI-2718
Cooley Patent Ductus Clamp - 6 1/4"
jaws calibrated at 5.0 mm intervals, 6-1/4" (16.0 cm)
Cooley Patent Ductus clamp is well suited for use in cardiothoracic surgical procedures. Specifically this clamp is designed for use in surgical procedures to repair a patent ductus. The jaws of this clamp are calibrated at 5 mm intervals and are designed for a firm surgical grip upon the vessels but is delicate enough to prevent any bruising or tears to the vessels walls themselves. This instrument is available with either straight or angular shanks making it possible to select the best fit possible for the procedure at hand.
Cooley Aorta Clamp
SKU:
TT-SI-2351
Cooley Aorta Clamp
Cooley Aorta Clamp is ideally suited for some cardiothoracic surgeries. This clamp is designed with a slight U-shaped hook shape to make a perfect tool for manipulation and clamping of the aorta. Additionally, these clamps are well suited for use in sectioning a specific portion of the aorta because they are created for easy handle a firm grip without causing any injury or damage to the vessel itself. This instrument is available in two different jaw lengths to make it suitable for use in a wide number of patients and surgeon preferences.
Cooley Aortic Aneurysm Clamp
SKU:
TT-SI-2373
Cooley Aortic Aneurysm Clamp
slightly curved jaws, jaws 7.6 cm, 10-3/4" (27.3 cm)
Cooley Aortic Aneurysm Clamp is made to be used cardiothoracic procedures that require clamping of the aorta, specifically at or around the site of aneurysm. This clamp can be used to in temporary occlusion of the aorta to resect fusiform aneurysms as well as provide additional support and stability in aortic grafting procedures. The slightly curved jaws gives this clamp the ability to contour to and seamlessly move through the surgical field causing the least amount of trauma to the aorta itself and surrounding tissue.
Cooley Neonatal Clamp
SKU:
TT-SI-2712
Cooley Neonatal Clamp
5" (12.5 cm)
Cooley Neonatal Clamp is the ideal tool for use in surgical procedures for newborn children. This clamp is build sturdily but made small enough to clamp the delicate vessels of a newborn child. This instrument is particularly well suited due to its ability to maintain a hold on the vessel without causing tears or rip on the delicate vessel walls of the newborn. Additionally, this clamp is available in a straight profile, spoon jawed, anastomosis clamp, carotid clamp or angled shank and straight jaws or curved shanks and angled jaws.
Cooley Tangential Occlusion Clamp
SKU:
TT-SI-8244
Cooley Tangential Occlusion Clamp
double angled jaws calibrated at 5.0 mm intervals, 7-3/4" (19.5 cm)
Cooley Tangential Occlusion Clamp is uniquely designed to clamp vessels in a way that reduces blood flow without completely stopping it in cardiothoracic surgical procedures. This clamp can be best used when doing procedures such as side-by-side anastomosis that required some blood flow. Additionally, this instrument features double angled jaws that are calibrated at 5 mm intervals making it possible to make accurate measurements during the procedure.
Cooley Anastomosis Clamp
SKU:
TT-SI-6776
Anastomosis Clamp
jaws calibrated at 5.0 mm intervals, 6-1/2" (16.5 cm)
Cooley Anastomosis Clamp is designed for use in cardiothoracic surgical procedures in which an anastomotic connection is to be formed between two vessels and blood flow needs to be reduce significantly via clamping. This instrument features jaws that are calibrated at 5 mm intervals making them ideally suited to give accurate measurement information during a surgical procedures. Additionally, this clamp features a slightly looped, u-shaped clamp to provide optimal gripping capacity but also maintaining that hold consistently throughout the procedure.
Reviews
There are no reviews yet.