Name | Dale Improved Femoral Popliteal Anastomosis Clamp |
Lead Time | Lead time advised within 48 hours of order placement. |
Specialty | Cardiothoracic-Cardiovascular Clamps |
Material Finish | Stainless Steel |
Grade | Premium Operating Room |
Units of Measurement | Each |
Manufacturer | Tool Tectra |
Sterility | Non-Sterile |
Usage | Reusable |
Popliteal Anastomosis Clamp
Popliteal Anastomosis Clamp
debakey jaws, jaws 4.0 cm, 7-1/4″ (18.5 cm)
Dale Improved Femoral Popliteal Anastomosis clamp is ideally suited for use in cardiothoracic surgical procedures. This is a highly versatile vascular clamp that can be used in procedures requiring a femoral popliteal anastomosis. Additionally, this clamp can be used when a broken-back small vascular clamp is required. This instrument is hand-crafted by certified instrument makers to conform to the highest standards in instrumentation.
SKU:
TT-SI-4557
Category: Cardiovascular Clamps
Description
Reviews (0)
Be the first to review “Popliteal Anastomosis Clamp” Cancel reply
Shipping & Delivery
Related products
Cooley Anastomosis Clamp
SKU:
TT-SI-6776
Anastomosis Clamp
jaws calibrated at 5.0 mm intervals, 6-1/2" (16.5 cm)
Cooley Anastomosis Clamp is designed for use in cardiothoracic surgical procedures in which an anastomotic connection is to be formed between two vessels and blood flow needs to be reduce significantly via clamping. This instrument features jaws that are calibrated at 5 mm intervals making them ideally suited to give accurate measurement information during a surgical procedures. Additionally, this clamp features a slightly looped, u-shaped clamp to provide optimal gripping capacity but also maintaining that hold consistently throughout the procedure.
Cooley Iliac Clamp
SKU:
TT-SI-7926
Cooley Iliac Clamp
Cooley Iliac Clamp allows for exquisite control of blood flow through large arteries during a number of orthopedic and cardiac procedures, or whenever temporary occlusion of the iliac vasculature is desired. Renowned for its ease of use, Cooley Iliac Clamp is designed for the application of variable pressures on the Iliac artery to prevent intrusive blood flow. It provides for a strong, secure and adjustable grip which can be used for closure of vasculature or secure clamping of soft tissue. The jaws are set at a slight angle so as to allow maneuverability while still maintaining pressure and control when clamping the intended area. This clamp features straight jaws, handles angled at 45 degrees and is available in two different jaws sizes.
Cooley Aortic Aneurysm Clamp
SKU:
TT-SI-2373
Cooley Aortic Aneurysm Clamp
slightly curved jaws, jaws 7.6 cm, 10-3/4" (27.3 cm)
Cooley Aortic Aneurysm Clamp is made to be used cardiothoracic procedures that require clamping of the aorta, specifically at or around the site of aneurysm. This clamp can be used to in temporary occlusion of the aorta to resect fusiform aneurysms as well as provide additional support and stability in aortic grafting procedures. The slightly curved jaws gives this clamp the ability to contour to and seamlessly move through the surgical field causing the least amount of trauma to the aorta itself and surrounding tissue.
Calman Carotid Clamp
SKU:
TT-SI-5646
Calman Carotid Clamp
angled shanks, long thin jaw, 25.0 mm, 4-1/4" (11.0 cm)
Calman Carotid Clamp is ideally suited for use in cardiothoracic surgical procedures specifically in surgeries that require clamping of the carotid vessels. This clamp feature angled shanks to increase the easy of access to the vessels as well as having a long thing jaw that allows it to move between deeper layers of tissue without displacing anything or injuring other organs of vasculature. This clamp is strong enough to provide the occluding force necessary but also is gentle enough to keep the carotid walls intact with minimal injury or bruising.
Cooley Cardiovascular Clamp – Fully-Curved
SKU:
TT-SI-6574
Fully-Curved
for temporary occulation of the iliac artery, 2-3/4" (7.0 cm) fully-curved jaws, 10-3/4" (27.3 cm)
Cooley Cardiovascular Clamp is ideally suited for use in cardiothoracic surgical procedures that require temporary occultation of the iliac artery. This instrument comes equipped with fully curved jaws making it particularly well suited for use in clamping vessels close to the diameter of the iliac vessels. The scissor grip handles and the ratcheting mechanism for keeping the clamp in place allows for this clamp to stay securely in place through the surgical procedure but is gentle enough to keep from injuring the vessel walls.
Cherry Supraceliac Clamp
SKU:
TT-SI-1517
Cherry Supraceliac Clamp
shanks curved 60 degrees, debakey 2x3 teeth, jaws 5-3/4", curved, 12-1/2" (31.0 cm)
Cheery Supraceliac Clamp is created to be of optimal use in cardiothoracic surgical procedures. This instrument is especially useful aortic aneurysm repairs of the abdominal and thoracic aorta particularly this clamp can be used in accessing the portion of the aorta that is found superior to the celiac artery. Curved shanks coupled with a 60 degree angle and DeBakey teeth allow this clamp to access some deeper vessel structures without damaging the vessel walls or the surrounding tissue.
Cooley Multi Purpose Clamp
SKU:
TT-SI-5166
Cooley Multi Purpose Clamp
jaws angled 60 degrees
Cooley Multi Purpose Clamp is designed for use in a variety of cardiothoracic surgeries that require clamping of vessels. These multi-purpose clamps are uniquely designed to accommodate a number of different surgical maneuvers instead of being made for one specific purpose. The multiple application of this instrument making it a valuable tool in the operating room because it is suitable for most all clamping situations. Additionally, the jaws come angled at 60 degrees and this instrument is available in three different jaw lengths making it easy to find a suitable instrument for any surgical maneuver or surgeon preferences.
Bailey Aorta Clamp
SKU:
TT-SI-1643
Bailey Aorta Clamp
angled shanks
Bailey Aorta Clamp are designed for use in cardiothoracic surgical procedures. This clamp is ideal for use when there is a surgical maneuver that requires exclusion of a specific portion of the vessel. The unique design of this clamp with the slightly angled shanks allows for this clamp to effectively reach and clamp off the aorta when other instruments may not be able to. Additionally, this instrument is available in three different jaw sizes: extra small, small and large making it well suited for a number of different vessel sizes but also in different levels of blood flow restriction.
Reviews
There are no reviews yet.